Article

Can industrial fuel Fan heater be used in flower greenhouses?

SIAL
Can we use fuel Fan heater in the flower shed? It was possible at that time! Oil fired Fan heater can be used in flower greenhouse breeding, and will not affect plants.
When the fuel Fan heater works, the fuel in the oil tank is sucked into the fuel injector, ignited and ignited after the combustion chamber is atomized. The ignition causes the heat to heat the air and combustion chamber wall, part of the air sent by the fan is sent to the combustion chamber to provide oxygen for combustion support, and the fuel oil Fan heater causes continuous high temperature heat flow, most of which touch the combustion chamber surface to get heat transmission, resulting in heat flow. This is the simple working principle of fuel Fan heater.
The following are the application benefits of fuel Fan heater in potted flowers:

1. Oil fired Fan heater has good consciousness and is not limited by address and space, which is different from the traditional electric heating, floor heating and water heating. In addition, the oil fired Fan heater is also easy to supply energy, and there are no more cables, water pipes, etc. In a word, the oil fired Fan heater is very convenient and simple to use in potted flowers.

2. The application of fuel oil Fan heater is very safe, and the fuel oil Fan heater can be used in the room if it is ignited sufficiently.

3. The fuel oil Fan heater can be moved. Where heating is necessary, the fuel oil Fan heater can be placed. It is convenient to move and will not be limited by the location.

4. Collapsible. When the weather gets warmer, the fuel Fan heater can be stopped. It is difficult to put away the radiator settings. It is only placed there for a long time. However, the fuel Fan heater is different. The fuel Fan heater can be disassembled and stored.
With the rapid development of the manufacturing industry, many machine development trends have significant advantages. For example, the overall design of the electric Fan heater is effective and beautiful, and the support frame is firm and beautiful. However, during use, there may be some abnormal phenomena in the air inlet. Let's talk about how to solve the problem of abnormal air outlet of the fan.

1. The electric Fan heater has a heavy odor in the wind: if the electric Fan heater blows out warm air with a heavy odor, check whether there is dirt at the vent. If not, please shut it down immediately. There may be some issues with the control line.
2. The temperature at the inlet and outlet of the electric Fan heater is relatively low: if the hot gas ambient temperature of the electric Fan heater is not too high or too hot, check that the ambient temperature set by the electric Fan heater is relatively low or the exhaust volume controller is set with too much air. If not, it should be considered whether the heating tube of the machine has significant heat loss, whether the electrode connection wire of the machine has fallen off, and whether the equipment and switch power supply are too small to meet the heating requirements.
3. The air volume of the electric Fan heater is too small: if it is found that the exhaust volume of the electric Fan heater is less than before during operation, it must be determined that the exhaust volume set by the exhaust volume controller of the machine equipment is small, and investigate whether the regulating switch operates normally. Is the ventilation opening blocked by dirt that restricts the transmission of warm air. What must be concerned is whether the filtering system of the electric Fan heater has not been cleaned for a long time, which has accumulated a lot of dust, resulting in poor natural ventilation.
4. Once it is found that there is no air in the electric Fan heater, the machine equipment may not work, so the first thing to determine is whether it is a circuit problem, whether the switch power supply is disconnected, and whether the start switch is turned on. Secondly, it is important to understand whether the switch power supply connected to the device is abnormal and whether the fuse of the control circuit has melted. Then you can confirm whether the power isolation switch has tripped and disconnected, and whether the wiring of the machine equipment is incorrect.
There may be some small problems in the process of using the electric Fan heater. Try to avoid all kinds of problems in use, and be sure to find out the causes and deal with them in a timely manner.
0 Comments
Leave a Comment
Your email address will not be published. Required fields are marked *
Submit Comment
Latest Exhibtions
Contact Now
Name:
Email:  Email is wrong!
Message:  Message is wrong!
SUBMIT
Contact us now
Forced Air Heater for Sale - Sial Heater
Am Seestern 840547 dusseldorf, Germany
You can trust us
We are a professional manufacturer of air heating equipment in China, and we continue to innovate in order to provide customers with better products and services.
© 2020 Sial        SiteMap.html    SiteMap.xml    Terms of Service      Privacy Policy
Marketing Support by Globalsir
Enter your inquiry details, We will reply you in 24 hours.
Name can't be empty
E-mail can't be empty
Company can't be empty
Phone can't be empty
Products can't be empty
Message can't be empty
Verification code error
code
Refill